5/5 on Google Reviews

Home Extension & New Build Electrical Wiring in Montrose

Complete electrical installation for home extensions, sunrooms, garage conversions, granny annexes and new build properties in Montrose and across Angus. Speak to James Leslie directly about the electrical design and the installation.

Call 01674 900550James answers · 24/7 for emergencies
  • Local, Montrose based electrician
  • First fix while the walls are open
  • Electrical Installation Certificate issued
  • Costs agreed before work begins
James Leslie

Get your extension wiring quote

Emergency or out of hours? Call 01674 900550, 24/7.

No obligation. Costs are agreed before any work begins.

  • 18th EditionBS 7671 Qualified
  • City & Guilds2382-22, Level 3
  • Fully InsuredFor Electrical Work
  • RAF ElectricianElectrical Engineer
  • Ex-Retained FirefighterFire & Rescue Service
The Montrose Sparks van parked in Montrose

Extension Wiring Across Montrose, Angus

Montrose Sparks is James Leslie, based in Montrose. Extension work here covers everything from a sunroom on a family home at Borrowfield or Hillside to an annexe on a rural plot, across DD10 and the approximate 40-mile radius he covers.

The time to plan the electrics is before the plasterboard goes on. James works from your drawings alongside the builder, so cable routes, socket positions and lighting are first-fixed while the frame is open. If the existing board cannot take the new circuits, see Fuse Box & Consumer Unit Upgrades. A kitchen in the new space comes under Kitchen Electrics & Cooker Installation, and alarm positions for the new rooms under Interlinked Smoke & Heat Alarms.

5/5 on Google Reviews

★★★★★Google Review
“He took great care over the work (even used a spirit level to make sure the cooker was sitting right!) and was very reasonably priced. We are new to the area and struck lucky finding a reliable, responsive electrician.”
Donna NZVerified
★★★★★Google Review
“Great service, fast response and problem fixed quickly”
Jen JVerified
★★★★★Google Review
“Great service highly recommended.”
Lee DuncanVerified
★★★★★Google Review
“Jamie arrived within 15 minutes of my call and had the power back on about 10 minutes later.”
megan mcgregorVerified
★★★★★Google Review
“James was very polite and sent over the quote immediately after the call and came out the same day in the early evening.”
SamanthaVerified
★★★★★Google Review
“He couldn't of been more helpful and still only took what he quoted for, even though it was a bigger job than expected. Definitely recommend.”
Tammy CrockattVerified
★★★★★Google Review
“Arrived within an hour of my call, as he said he would. Fixed the problem same afternoon, and rate was extremely reasonable!”
Sarah DundasVerified
★★★★★Google Review
“They also give decent price for the job and the work done will be using James again, he is also very polite and very helpful too me.”
katieVerified
★★★★★Google Review
“Fast response during a weekend, put in a temporary fix so we got power back. Excellent service.”
Ian MilneVerified
★★★★★Google Review
“Very professional and courteous. Highly recommend him.”
BuckyVerified
★★★★★Google Review
“James answered my call late at night and went to my property to investigate even though I had never used him before.”
Mohan ThiagarajahVerified

Why Choose Montrose Sparks for Your Extension Wiring?

  • Montrose Sparks wires extensions and new builds across Montrose, Angus

    Complete electrical installation for home extensions, sunrooms, garage conversions, granny annexes and new build properties. James works from Montrose and covers an approximate 40-mile radius.

  • Work is carried out to BS 7671 by an 18th Edition qualified electrician

    James issues an Electrical Installation Certificate (EIC) for the electrical work, and any applicable building warrant or approved certification requirements for the extension are agreed.

  • You deal directly with James Leslie, not a call centre

    There is no office between you and the electrician. James has 40 years of electrical engineering experience across military, municipal and private sectors, including service as an RAF electrical engineer and as a retained firefighter.

  • Montrose Sparks is fully insured and locally based

    The business carries public liability cover for domestic, commercial and agricultural properties. Costs are agreed before any work begins.

More about James
James carrying out an electrical inspection at a property
Coordinated with your building contractors, from first fix to the certificate.

Before the plasterboard goes on

Will My Consumer Unit Cope With an Extension?

Often, yes. A board with spare ways and the right RCD or RCBO protection can usually take the circuits a single-storey extension or garage conversion adds. Sometimes it cannot, and a new consumer unit or a sub-main to a separate board is the better route. Which applies is assessed at first-fix planning, from the existing board and your drawings. Building an extension or converting a garage requires careful integration with your property’s existing electrical system.

  • New circuits for the new rooms

    Full routing of power, lighting, heating, and data cabling followed by high-quality faceplate installation.

  • Board capacity: extended, replaced or a sub-main

    Adding sub-distribution boards to support large annexes or extending existing board circuits with proper RCD/RCBO protection.

  • First fix with your builder

    We coordinate with your building contractors to install first-fix cabling, sub-distribution boards, lighting, heating controls, and outdoor connections efficiently.

  • Testing and certification

    Providing an Electrical Installation Certificate (EIC) for the electrical work and agreeing any applicable building warrant or approved certification requirements for the extension.

Not sure what your board can take? Send a photo of it with the drawings.

Complete Electrical Solutions for Building Extensions

Three kinds of project, and how the wiring and the supply are arranged for each.

  • single-storey rear extension under construction

    Single-Storey Extension Electrical Installation

    The new rooms get their own socket and lighting circuits, with heating controls, outdoor connections and any data points routed while the frame is open and run back to the existing consumer unit. Faceplates, fittings and heating controls go on after plastering.

  • James looking at a fitted light in a wooden garden workshop

    Garage Conversion Wiring

    A converted garage usually needs its own circuits rather than the old garage supply: sockets, lighting and heating cabled from the main house on a route agreed with the builder, with RCD/RCBO protection at the board. Any existing garage wiring is checked before it is reused.

  • James discussing lighting with a homeowner in a finished extension

    Granny Annexe Sub-Mains & Complete Wiring

    A self-contained annexe is usually fed by a sub-main: one larger cable from the main board to a sub-distribution board in the annexe, which then carries its own kitchen, shower, heating, lighting and socket circuits. Independent metering, where wanted, is discussed at the planning stage.

How Much Does Extension Wiring Cost?

Guide prices run from £800 – £2,000+ for a garage conversion to £2,500 – £5,500+ for a granny annexe with sub-mains. Comprehensive installation quotes are agreed upfront against your building plans.

Single-Storey Extension Electrical InstallationNumber of sockets, lighting layout, heating integration. Share architectural plans or building specification drawings.
£1,200 – £3,000+Typical single-storey extension
Garage Conversion WiringCable route from main house, heating type, consumer unit setup. Quoted after site survey or plan review.
£800 – £2,000+Typical garage conversion
Granny Annexe Sub-Mains & Complete WiringSub-board installation, independent metering, kitchen/shower setup. Quoted against architectural layouts and structural specifications.
£2,500 – £5,500+Annexe with its own sub-board

Indicative guide prices. The final scope and cost are agreed before work begins.

Full pricing guide

How the job runs

What Does Extension Wiring Involve?

The electrics follow the build: positions are set from the drawings, cables go in while the frame is open, and fittings go on once the plaster is dry.

  1. 1

    Plan positions from the drawings

    Socket, switch, light and heating positions are agreed with you and the builder from the architectural plans, along with the cable route back to the board and where any sub-board will sit.

  2. 2

    First fix while the frame is open

    Cables, back boxes and containment are run through the studwork, joists and floor void before insulation and plasterboard go on, coordinated with the builder’s programme.

  3. 3

    Consumer unit work, sub-main or new circuits

    The new circuits are connected at the existing consumer unit where it has the capacity and protection, or a new board or a sub-main to a sub-distribution board is installed where it does not.

  4. 4

    Second fix after plastering

    Faceplates, switches, light fittings, heating controls and any outdoor connections are fitted and connected once the walls and ceilings are finished.

  5. 5

    Inspection, testing and certification

    Every new circuit is inspected and tested to BS 7671, and an Electrical Installation Certificate (EIC) is issued for the electrical work.

On completion

What you are left with

The paperwork handed over when the extension wiring is signed off.

  • Electrical Installation Certificate (EIC)

    Records the new circuits, any board or sub-main work, and the inspection and test results for the electrical work. It covers the stated work rather than certifying every unrelated part of the existing installation.

  • Circuit schedule

    The new circuits labelled at the consumer unit or sub-board, so you and the builder know which device protects the extension’s sockets, lighting and heating.

  • Building warrant and certification

    Any applicable building warrant or approved certification requirements are assessed separately. What the electrical work needs to show for the extension is agreed with you before it starts.

While the ceilings are open

Smoke and Heat Alarms When You Extend

Extending, converting or altering a home can change what alarms it needs, because the rooms and circulation spaces, and how they are used, change with it. Alarm coverage for the new layout is checked as part of the job, and any new or repositioned units are wired in at first fix while the ceilings are open. The Scottish Government’s guidance on home extension, alterations and conversion work explains why building standards and any warrant requirements must also be considered.

Extension Wiring Across Montrose, Angus

Extensions, garage conversions and annexes in the Angus towns, the Mearns and the rural plots in between. James is based in Montrose, Angus, Scotland, and covers the DD10 postcode district within an approximate 40-mile radius. Give him your postcode to confirm availability.

  • Montrose and DD10The town, Ferryden and Hillside, and up the coast to St Cyrus. Our base, so usually the quickest to arrange.
  • Brechin and ForfarExtensions, garage conversions and annexes for homeowners, builders and architects across the Angus towns.
  • ArbroathNew builds and annexes, including surrounding rural properties.
  • Laurencekirk and InverbervieEnquiries welcome for houses, flats and rented properties.
  • Elsewhere in Angus and the MearnsDundee and Stonehaven are inside the approximate 40-mile service area. Call with your postcode to check coverage.
Map of the Montrose Sparks service area: about 40 miles around Montrose, across Angus and the Mearns to DundeeNorth Sea10 mi20 mi30 mi40-MILE SERVICE AREABrechinForfarArbroathDundeeKirriemuirLaurencekirkCarnoustieStonehavenInverbervieMontrose

Inside the service area

Brechin

About 7 miles from Montrose, as the crow flies

Call 01674 900550

Frequently Asked Questions About Extension Wiring

Can’t see your question?

James answers the phone himself and will tell you straight away whether he can help.

Call 01674 900550
When should I involve an electrician in an extension?

At drawing stage, before the builder starts. Socket, switch, light and heating positions and the route back to the board are easiest to settle from the plans, and the first fix has to go in before the plasterboard. Send James the architectural plans or building specification drawings with your enquiry and he can quote and plan the first fix around the builder’s programme.

Will an extension need a new consumer unit?

Not always. A board with spare ways and the right RCD or RCBO protection can often take the new circuits; an older board, one with no spare ways, or one without the protection the new circuits need may be better replaced, or fed by a sub-main to a separate board. James assesses the existing board at first-fix planning and agrees any board work with you before it starts.

Does a garage conversion need new circuits?

Usually, yes. A garage supply was typically put in for a light and a socket or two, and a converted room needs its own socket, lighting and heating circuits with RCD/RCBO protection at the board. Whether any existing garage wiring can be kept is assessed on site, and the cable route from the main house is one of the things that sets the price.

What is a sub-main and does an annexe need one?

A sub-main is a single larger cable run from the main consumer unit to a second board, which then supplies its own circuits. A self-contained annexe with a kitchen, shower and heating is often better served by a sub-main and its own sub-distribution board than by running every circuit back to the house, but it depends on the load, the distance and what the main board can take. James assesses this against the layouts and structural specifications and agrees the arrangement before work starts.

Do I need a certificate for extension wiring?

Yes. New circuits, consumer unit work and sub-mains are recorded on an Electrical Installation Certificate (EIC) covering the inspection and test results for the electrical work. Any applicable building warrant or approved certification requirements are assessed separately.

Will my new extension need smoke alarms?

It may, and it depends on the layout. Extending or converting a home can change the rooms and circulation spaces that need cover, so alarm provision is checked as part of the job rather than assumed. The Scottish Government’s guidance on home extension, alterations and conversion work sets out the current requirements, and James plans any new or repositioned alarms at first fix, while the ceilings are open.

Get your extension wiring quote

Say what you are building (an extension, garage conversion, annexe or new build) and send the architectural plans or building specification drawings if you have them. James agrees the quote upfront against your building plans.

James aims to reply within one hour, 8am–6pm.

Tap to call 01674 900550
James Leslie

Get a free quote

Replies within an hour, 8am–6pm.

Emergency or out of hours? Call 01674 900550, 24/7.

No obligation. Costs are agreed before any work begins.