5/5 on Google Reviews

Solar PV Maintenance & Inverter Repairs in Montrose

Solar PV system health checks, inverter replacements and electrical fault finding for domestic rooftop arrays, commercial solar setups and farm systems in Montrose and across Angus. Speak to James Leslie directly about getting your solar generation back to where it should be.

Call 01674 900550James answers · 24/7 for emergencies
  • Montrose based, 40-mile radius
  • Inverter fault lights and error codes diagnosed
  • Rooftop DC isolators and cabling repaired
  • Costs agreed before work begins
James Leslie

Get your solar PV maintenance quote

Emergency or out of hours? Call 01674 900550, 24/7.

No obligation. Costs are agreed before any work begins.

  • 18th EditionBS 7671 Qualified
  • City & Guilds2382-22, Level 3
  • Fully InsuredFor Electrical Work
  • RAF ElectricianElectrical Engineer
  • Ex-Retained FirefighterFire & Rescue Service
The Montrose Sparks van parked in Montrose

Solar PV Repairs Across Montrose, Angus

Montrose Sparks is James Leslie, based in Montrose. Arrays here sit on house roofs in the town and in Hillside and Ferryden, and on farm buildings in Angus and the Mearns. He covers DD10 and an approximate 40-mile radius.

If your solar has stopped generating, James does the diagnostic, the repair and the written results. Where the fault is on the AC side of the installation and not in the solar equipment, it is handled as Electrical Repairs & Fault Finding. Whether an older inverter can work with Home Battery Storage is checked after assessing the existing array, equipment, supply and proposed battery. At the same visit James can advise on Surge Protection for the inverter and connected equipment.

5/5 on Google Reviews

★★★★★Google Review
“He took great care over the work (even used a spirit level to make sure the cooker was sitting right!) and was very reasonably priced. We are new to the area and struck lucky finding a reliable, responsive electrician.”
Donna NZVerified
★★★★★Google Review
“Great service, fast response and problem fixed quickly”
Jen JVerified
★★★★★Google Review
“Great service highly recommended.”
Lee DuncanVerified
★★★★★Google Review
“Jamie arrived within 15 minutes of my call and had the power back on about 10 minutes later.”
megan mcgregorVerified
★★★★★Google Review
“James was very polite and sent over the quote immediately after the call and came out the same day in the early evening.”
SamanthaVerified
★★★★★Google Review
“He couldn't of been more helpful and still only took what he quoted for, even though it was a bigger job than expected. Definitely recommend.”
Tammy CrockattVerified
★★★★★Google Review
“Arrived within an hour of my call, as he said he would. Fixed the problem same afternoon, and rate was extremely reasonable!”
Sarah DundasVerified
★★★★★Google Review
“They also give decent price for the job and the work done will be using James again, he is also very polite and very helpful too me.”
katieVerified
★★★★★Google Review
“Fast response during a weekend, put in a temporary fix so we got power back. Excellent service.”
Ian MilneVerified
★★★★★Google Review
“Very professional and courteous. Highly recommend him.”
BuckyVerified
★★★★★Google Review
“James answered my call late at night and went to my property to investigate even though I had never used him before.”
Mohan ThiagarajahVerified

Why Choose Montrose Sparks for Your Solar PV Repairs?

  • Montrose Sparks maintains solar PV systems across Montrose, Angus

    Solar PV system health checks, inverter replacements and electrical fault finding for domestic rooftop arrays, commercial solar setups and farm systems. James works from Montrose and covers an approximate 40-mile radius.

  • Work is carried out to BS 7671 by an 18th Edition qualified electrician

    Solar panels can produce dangerous DC voltages whenever they are exposed to light, even with the AC supply switched off. James tests string voltages, AC output levels, generation meters and earthing continuity to investigate how the system is performing.

  • You deal directly with James Leslie, not a call centre

    James answers the phone, does the work and signs it off. He has 40 years of electrical engineering experience across military, municipal and private sectors, and served as an RAF electrical engineer and as a retained firefighter.

  • Montrose Sparks is fully insured and locally based

    James holds public liability insurance for work in domestic, commercial and agricultural properties. Clear diagnosis and repair quotes are agreed before work begins.

More about James
James carrying out an electrical inspection at a property
DC and AC sides of the system tested before any component is condemned.

When to call

Why Has My Solar Inverter Stopped Generating?

Common causes include grid voltage fluctuations, internal capacitor failure, faulty DC isolators, or blown internal fuses. An electrical diagnostic pinpoints the exact component failure. Inverter degradation, connection faults, or damaged meters can reduce generation or stop the system operating.

  • A red fault light, error code or silent shutoff

    Red fault lights, error codes, grid-sync failures, or silent inverter shutoffs are diagnosed first. Faulty string or micro-inverters are replaced with modern, high-efficiency replacement units.

  • A damaged DC isolator, corroded connector or damaged cabling

    Damaged DC isolator switches, corroded connector plugs, and damaged solar cabling are replaced to prevent dangerous DC arcing and fire hazards.

  • Generation lower than you expect

    String voltages, AC output levels, generation meters, and earthing continuity are tested to investigate system performance. Output depends on sunlight, shading, equipment condition and the system design.

  • No electrical health check in the last 3 to 5 years

    A technical electrical health check is recommended every 3 to 5 years to verify string insulation, isolator integrity, and electrical safety.

Not sure what the error code means? Send James a photo of the inverter display.

Signs Your Solar PV Needs Attention

A solar fault does not always announce itself. These are the signs owners usually describe when they call, and what each one can point to:

  • Your generation figure has dropped or reads zero

    A generation meter or monitoring app showing nothing on a bright day, or a figure well below what the system produced in earlier years, can point to an inverter, isolator or connection fault. Output depends on sunlight, shading, equipment condition and the system design, so a diagnostic establishes which it is rather than guessing.

  • An inverter fault light or error code

    A red light, a blank display or an error code on the inverter can indicate a grid-sync failure, an internal fault or a problem on the DC side. Note the code and, if you can safely reach the display, take a photo of it before calling.

  • Tripping when the sun comes out

    If a breaker or RCD trips in daylight and holds overnight, the fault may lie in the solar circuit rather than elsewhere in the installation. Leave the circuit off and arrange a diagnostic rather than resetting it repeatedly.

  • A damaged isolator or cabling on the roof

    Weathered DC isolators, cracked connector plugs or cabling that has come loose from its clips can lead to dangerous DC arcing. Solar panels can produce dangerous DC voltages whenever exposed to light, even if the AC supply is switched off, so do not open or handle roof equipment yourself.

Call 01674 900550Describe what the inverter is showing and James will advise on the next step.

Essential Solar PV System Diagnostics & Servicing

Solar PV systems contain DC wiring, inverters, and AC isolators. Solar panels can produce dangerous DC voltages whenever exposed to light, even if the AC supply is switched off. Inverter degradation, connection faults, or damaged meters can reduce generation or stop the system operating.

  • James and a homeowner looking towards a garden room

    Solar Inverter Fault Finding & Replacements

    Diagnosing red fault lights, error codes, grid-sync failures, or silent inverter shutoffs. We replace faulty string or micro-inverters with modern, high-efficiency replacement units.

  • James talking with an older homeowner in her sitting room

    Rooftop DC Isolator & Wiring Repairs

    Replacing damaged DC isolator switches, corroded connector plugs, and damaged solar cabling to prevent dangerous DC arcing and fire hazards.

  • James discussing an inspection with a business owner

    System Performance Health Checks & Generation Verification

    Testing string voltages, AC output levels, generation meters, and earthing continuity to investigate system performance. Output depends on sunlight, shading, equipment condition and the system design.

How Much Does Solar PV Maintenance Cost?

A solar PV system health check and diagnostic is £80 – £250+, a string inverter replacement £600 – £1,500+, and a DC isolator and cable replacement £120 – £350+. Prices depend on inverter access, roof layout, the inverter kW rating and the DC cabling run length. All costs are agreed before work begins.

Solar PV System Health Check & DiagnosticAccess to inverter, roof layout, string testing required. Describe error codes, inverter brand, and age of system.
£80 – £250+Diagnostic visit
String Inverter ReplacementInverter kW rating, single/three-phase, AC/DC isolator replacement. Quoted for replacement hardware and installation testing.
£600 – £1,500+Replacement hardware and testing
DC Isolator & Cable ReplacementRoof access, isolator type, DC cabling run length. Quoted following diagnostic assessment of damaged isolators.
£120 – £350+After diagnostic assessment

Indicative guide prices. The final scope and cost are agreed before work begins.

Full pricing guide

What Does a Solar PV Fault Diagnostic Involve?

Whether the system has stopped altogether or is generating less than it should, the visit follows the same order: find the fault first, then agree the repair.

  1. 1

    The history and any generation records

    James takes the history from you: when the system stopped or dropped off, what the inverter is showing, and any generation figures, monitoring app data or previous reports you have. Describe error codes, inverter brand, and age of system.

  2. 2

    Visual inspection of the inverter, isolators and accessible cabling

    The inverter, the AC and DC isolators and the cabling that can be reached safely are inspected for damage, corrosion, overheating and loose connections. Solar panels can produce dangerous DC voltages whenever exposed to light, even if the AC supply is switched off, so the DC side is treated as live throughout.

  3. 3

    Electrical tests of the AC and DC sides

    As appropriate to the fault, string voltages, AC output levels, generation meters, and earthing continuity are tested to investigate system performance. The aim is to identify the failed component before anything is condemned or replaced.

  4. 4

    Repair or replacement of the faulty component, where agreed

    Faulty string or micro-inverters are replaced with modern, high-efficiency replacement units, and damaged DC isolator switches, corroded connector plugs, and damaged solar cabling are replaced to prevent dangerous DC arcing and fire hazards. The repair is quoted following the diagnostic assessment and agreed before it goes ahead.

  5. 5

    Recommissioning and confirmation of generation

    Once the repair is complete the system is switched back on in the correct sequence, the inverter is checked for a normal grid connection and generation is confirmed with you at the display or meter, so far as the daylight on the day allows. The readings are recorded on the written report.

On completion

What you are left with

A solar fault visit should leave you knowing what was found, what was tested and what was replaced. After the work James provides:

  • Written health-check report

    A written record of what was inspected and tested, with the test readings and photographs of the inverter, isolators and any damaged equipment found, so you can see why a repair was recommended.

  • Certificate for the replacement work

    A Minor Electrical Installation Works Certificate for a like-for-like replacement on the existing circuit, or an Electrical Installation Certificate where the work involves a new circuit, with the test results recorded.

  • Manufacturer paperwork for a new inverter

    The manufacturer’s instructions and the paperwork supplied with a replacement inverter, kept with your report for future servicing or a later battery storage assessment.

Solar PV Repairs Across Montrose, Angus

James is based in Montrose, Angus, Scotland, and covers the DD10 postcode district, the Angus towns and the Mearns within an approximate 40-mile radius. That takes in roof-mounted arrays on farms and rural homes, and inverters tucked into lofts, garages and outbuildings. Give him your postcode to confirm availability.

  • Montrose and DD10The town, Ferryden and Hillside, and up the coast to St Cyrus. Our base, so usually the quickest to arrange.
  • Brechin and ForfarDomestic rooftop arrays and commercial solar setups across the Angus towns.
  • ArbroathInverter repairs and health checks, including farm systems on surrounding rural properties.
  • Laurencekirk and InverbervieEnquiries welcome for houses, flats and rented properties.
  • Elsewhere in Angus and the MearnsDundee and Stonehaven are inside the approximate 40-mile service area. Call with your postcode to check coverage.
Map of the Montrose Sparks service area: about 40 miles around Montrose, across Angus and the Mearns to DundeeNorth Sea10 mi20 mi30 mi40-MILE SERVICE AREABrechinForfarArbroathDundeeKirriemuirLaurencekirkCarnoustieStonehavenInverbervieMontrose

Inside the service area

Brechin

About 7 miles from Montrose, as the crow flies

Call 01674 900550

Frequently Asked Questions About Solar Maintenance

Can’t see your question?

James answers the phone himself and will tell you straight away whether he can help.

Call 01674 900550
Why has my solar inverter stopped generating?

Common causes include grid voltage fluctuations, internal capacitor failure, faulty DC isolators, or blown internal fuses. An electrical diagnostic pinpoints the exact component failure.

Why is my solar generating less than it used to?

It may be one of several things. Output depends on sunlight, shading, equipment condition and the system design, so a drop can be as simple as new shading from a tree or building, or it can be a fault: inverter degradation, connection faults, or damaged meters can reduce generation or stop the system operating. A health check tests string voltages, AC output levels, generation meters, and earthing continuity to investigate system performance, and James explains what is found before any repair is quoted.

Can you replace a solar inverter?

Yes. Faulty string or micro-inverters are replaced with modern, high-efficiency replacement units, quoted for replacement hardware and installation testing. What affects the price is the inverter kW rating, single/three-phase, AC/DC isolator replacement. If you are also thinking about battery storage, compatibility must be checked before equipment is selected, so mention it when you enquire.

Is it safe to switch off my solar system myself?

Only the AC side, and only at the isolator or breaker you know to be the solar circuit. Solar panels can produce dangerous DC voltages whenever exposed to light, even if the AC supply is switched off, so do not open the inverter, operate roof-mounted DC isolators or handle solar cabling yourself. If something is burning or arcing, keep clear and call James on 01674 900550; if there is a fire, call 999.

Can I upgrade my old solar inverter to work with battery storage?

It may be possible. A compatible hybrid inverter or a separate AC-coupled battery system can be considered after assessing the existing array, equipment, supply and proposed battery. Compatibility must be checked before equipment is selected.

How often should a solar PV system be serviced?

A technical electrical health check is recommended every 3 to 5 years to verify string insulation, isolator integrity, and electrical safety.

Get your solar PV maintenance quote

Tell James the error code or fault light that is showing, the inverter brand and the age of the system. A clear diagnosis and repair quote is agreed before work begins.

James aims to reply within one hour, 8am–6pm.

Tap to call 01674 900550
James Leslie

Get a free quote

Replies within an hour, 8am–6pm.

Emergency or out of hours? Call 01674 900550, 24/7.

No obligation. Costs are agreed before any work begins.