5/5 on Google Reviews

Surge Protection Installation in Montrose

Find out whether surge protection is appropriate for your installation. James looks at the existing consumer unit and explains the suitable options, along with any electrical upgrades you already have planned.

Call 01674 900550James answers · 24/7 for emergencies
  • Retrofit or new board, assessed first
  • Fitted to the manufacturer’s instructions
  • Certificate issued for the work
  • Costs agreed before work begins
James Leslie

Get your surge protection quote

Emergency or out of hours? Call 01674 900550, 24/7.

No obligation. Costs are agreed before any work begins.

  • 18th EditionBS 7671 Qualified
  • City & Guilds2382-22, Level 3
  • Fully InsuredFor Electrical Work
  • RAF ElectricianElectrical Engineer
  • Ex-Retained FirefighterFire & Rescue Service
The Montrose Sparks van parked in Montrose

Surge Protection Devices in Montrose, Angus

Montrose Sparks is James Leslie, based in Montrose. He assesses surge protection for houses in the town, for farms in Angus and the Mearns on long rural supplies and for businesses with equipment they cannot afford to lose, within an approximate 40-mile radius.

The work covers homes, farms and businesses across Angus and surrounding areas. It is either an SPD added to an existing board or one specified as part of a consumer unit replacement. Properties with solar panels and rented homes due a landlord EICR are assessed the same way: the board is checked before anything is proposed.

5/5 on Google Reviews

★★★★★Google Review
“He took great care over the work (even used a spirit level to make sure the cooker was sitting right!) and was very reasonably priced. We are new to the area and struck lucky finding a reliable, responsive electrician.”
Donna NZVerified
★★★★★Google Review
“Great service, fast response and problem fixed quickly”
Jen JVerified
★★★★★Google Review
“Great service highly recommended.”
Lee DuncanVerified
★★★★★Google Review
“Jamie arrived within 15 minutes of my call and had the power back on about 10 minutes later.”
megan mcgregorVerified
★★★★★Google Review
“James was very polite and sent over the quote immediately after the call and came out the same day in the early evening.”
SamanthaVerified
★★★★★Google Review
“He couldn't of been more helpful and still only took what he quoted for, even though it was a bigger job than expected. Definitely recommend.”
Tammy CrockattVerified
★★★★★Google Review
“Arrived within an hour of my call, as he said he would. Fixed the problem same afternoon, and rate was extremely reasonable!”
Sarah DundasVerified
★★★★★Google Review
“They also give decent price for the job and the work done will be using James again, he is also very polite and very helpful too me.”
katieVerified
★★★★★Google Review
“Fast response during a weekend, put in a temporary fix so we got power back. Excellent service.”
Ian MilneVerified
★★★★★Google Review
“Very professional and courteous. Highly recommend him.”
BuckyVerified
★★★★★Google Review
“James answered my call late at night and went to my property to investigate even though I had never used him before.”
Mohan ThiagarajahVerified

Why Choose Montrose Sparks for Surge Protection?

  • Montrose Sparks assesses and fits surge protection across Montrose, Angus

    SPDs added to an existing consumer unit, and SPDs specified as part of a board replacement, for homes, farms and businesses. James works from Montrose and covers an approximate 40-mile radius.

  • Work is carried out to BS 7671 by an 18th Edition qualified electrician

    James selects the device for the board and the earthing arrangement and fits it to the manufacturer’s instructions. He then inspects, tests and records it and issues the appropriate certificate for the work.

  • You deal directly with James Leslie, not a call centre

    Your call goes to James Leslie in Montrose. He is a former RAF electrical engineer and former retained firefighter with 40 years of electrical engineering experience. Small jobs are welcome, and he explains the work clearly and agrees the cost before starting.

  • Montrose Sparks is fully insured and locally based

    The business carries public liability cover for domestic, commercial and agricultural properties. Costs are agreed before any work begins.

More about James
James carrying out an electrical inspection at a property
The board, the earthing and the manufacturer’s range are checked before a retrofit or a wider upgrade is proposed.

Retrofit or upgrade

Can Surge Protection Be Added Without a Full Replacement?

Sometimes. It depends on the existing equipment and installation. James will explain whether a suitable retrofit or a wider upgrade makes more sense.

  • Consumer unit compatibility

    James checks the existing consumer unit, available space and manufacturer-compatible equipment before discussing a retrofit.

  • Retrofit options

    A protective device should not be selected solely because it appears to fit an empty space. A compatible device for that board, or a separate enclosure beside it, may be the right answer.

  • Adding protection during an upgrade

    A consumer unit replacement or other planned installation work is an opportunity to assess the appropriate surge protection.

  • Checking an existing SPD

    Some devices have a status indicator showing when attention is needed. Do not remove consumer unit covers to inspect the device yourself.

Not sure what board you have? Send a photo of the consumer unit.

What a Surge Protection Device Does and Does Not Do

Three things people ask about an SPD: what it protects, what it will not do, and where it goes in the board.

  • James discussing an inspection with a business owner

    What an SPD does

    A Surge Protection Device (SPD) helps limit transient overvoltages that can affect electrical equipment. It works alongside earthing, bonding and other protective measures. It is fitted at the consumer unit, so the protection applies to the circuits fed from that board rather than to a single socket or appliance.

  • James discussing options with a homeowner in her warmly lit sitting room

    What it does not do

    An SPD reduces the risk; it does not remove it. It does not replace RCD protection or guarantee that appliances will survive every surge or lightning event. Surge protection is one part of an installation and is not a guarantee against every damaging event.

  • James listening to a homeowner while looking around a hallway

    Where it fits in the consumer unit

    The SPD takes a way in the board close to the main switch, connected through its own protective device as the manufacturer requires. Some installations need a different arrangement or further work. Where the existing board has no suitable space, James may propose a separate enclosure beside it or including the SPD in a consumer unit replacement.

Planning Protection During an Upgrade

The equipment, supply arrangement and installation requirements determine the proposal. Any extra work is explained before it is agreed.

A new EV charger, a heat pump, a solar or battery system or a new consumer unit each change what the installation carries and what is worth protecting, so surge protection is assessed at the same time rather than as an afterthought. Where the existing board has no suitable space, it is often simpler to include the SPD in the replacement than to retrofit it now and change the board later.

Planning a board change or a new circuit? Ask about surge protection at the same time.

How Is Surge Protection Priced?

There is no fixed price for an SPD because the board it goes into decides most of the work.

  • Quote agreed after assessment

    The equipment, access, investigation needed and extent of installation or repair affect the price.

  • Costs explained before you proceed

    James explains the proposed work and any additional costs before you agree to proceed.

  • What can be fitted depends on the board

    Compatibility, available space and the existing earthing arrangement influence what can be fitted.

Where the SPD is specified as part of a consumer unit replacement, it is included in the quote for that job rather than priced as a separate visit.

How Is a Surge Protection Device Fitted?

Adding an SPD to an existing board is a contained job; the checks before and after it are what make it worth doing.

  1. 1

    Check the board, earthing and available ways

    James confirms the consumer unit type, the earthing arrangement and whether there is a spare way for the SPD and its protective device, and identifies the manufacturer-compatible equipment for that board.

  2. 2

    Isolate the supply

    The installation is switched off and proved dead before any cover comes off. Tell James in advance if the board feeds anything that cannot be switched off without warning.

  3. 3

    Fit the SPD and its protective device

    The SPD is mounted in the board, or in a separate enclosure beside it where the board has no suitable space, with the overcurrent protection the manufacturer requires.

  4. 4

    Connect and label

    The connecting leads are kept as short as the layout allows and made as the manufacturer’s instructions describe, and the device is labelled so it can be identified at the board.

  5. 5

    Test, record and show you the indicator

    The installation is tested, the results are recorded on the certificate, and James shows you the status indicator and what a change in it means.

If testing shows a fault elsewhere in the installation, James explains it and agrees any further work with you before going on.

On completion

What you are left with

Paperwork and records handed over when the work is signed off.

  • Minor Electrical Installation Works Certificate

    Issued when an SPD is added to an existing consumer unit. It records the alteration, the inspection and the test results for that work; it does not certify the rest of an older installation.

  • Electrical Installation Certificate (EIC)

    Issued where the SPD is fitted as part of a consumer unit replacement, covering the new board as a whole. Any applicable building warrant or approved certification requirements are assessed separately.

  • Manufacturer’s instructions and indicator guidance

    The instructions for the fitted device, with a note of what its status indicator shows. Refer to the manufacturer’s instructions and arrange an assessment if the indication changes or damage is suspected.

Surge Protection Across Montrose, Angus

James is based in Montrose, Angus, Scotland, and covers the DD10 postcode district, the Angus towns and the Mearns within an approximate 40-mile radius. Surge protection is worth asking about for rural properties on overhead supplies, farms with electrically driven equipment and home offices with sensitive electronics. Give him your postcode to confirm availability.

  • Montrose and DD10The town, Ferryden and Hillside, and up the coast to St Cyrus. Our base, so usually the quickest to arrange.
  • Brechin and ForfarHomes, rentals and business premises across the Angus towns.
  • ArbroathRetrofits and consumer unit upgrades, including surrounding rural properties and farms.
  • Laurencekirk and InverbervieEnquiries welcome for houses, flats and rented properties.
  • Elsewhere in Angus and the MearnsDundee and Stonehaven are inside the approximate 40-mile service area. Call with your postcode to check coverage.
Map of the Montrose Sparks service area: about 40 miles around Montrose, across Angus and the Mearns to DundeeNorth Sea10 mi20 mi30 mi40-MILE SERVICE AREABrechinForfarArbroathDundeeKirriemuirLaurencekirkCarnoustieStonehavenInverbervieMontrose

Inside the service area

Brechin

About 7 miles from Montrose, as the crow flies

Call 01674 900550

Frequently Asked Questions About Surge Protection

Can’t see your question?

James answers the phone himself and will tell you straight away whether he can help.

Call 01674 900550
Can surge protection be added without a full replacement?

Sometimes. It depends on the existing equipment and installation. James will explain whether a suitable retrofit or a wider upgrade makes more sense.

Is surge protection required in a new consumer unit?

Surge protection is considered as part of the design whenever a consumer unit is replaced under the current wiring regulations, and the assessment decides whether an SPD is fitted. An existing board that is not being altered is not automatically required to have one. When James quotes a consumer unit replacement, the SPD is assessed and included in the proposal where it is appropriate.

Does an SPD protect against lightning?

Not fully. An SPD helps limit the transient overvoltages that lightning activity on or near the supply network can cause; a direct strike on a building is a separate matter, dealt with by a lightning protection system rather than a device in the consumer unit. It does not replace RCD protection or guarantee that appliances will survive every surge or lightning event. James explains what the device is for and where its limits are before it is fitted.

How do I know if my board has surge protection?

Look for a labelled SPD module with a small status indicator window, often next to the main switch, or a note of it on the circuit schedule or the certificate issued when the board was fitted. Do not remove consumer unit covers to inspect the device yourself. If you are not sure, send James a photo of the board with its cover on and he will tell you what is there.

Do SPDs wear out?

They can. The device works by diverting surge energy, and after a large event or over time it can reach the end of its useful life. Many have an indicator that changes to show when the module needs replacing, and some use a replaceable cartridge rather than a whole new device. Glance at the indicator now and then without removing the cover, and arrange an assessment if it changes or damage is suspected.

Will surge protection protect my solar inverter or EV charger?

It can help, but it depends on the installation. An SPD at the consumer unit covers the circuits fed from that board; a solar inverter, a battery or an EV charger may also need protection of its own, on the DC side or at the charger, as the manufacturer specifies. Whether what is in place is enough is assessed with the installation rather than assumed. Tell James what is connected and he will include it in the assessment.

Can I fit a plug-in surge protector instead?

A plug-in protector does a different job. It sits between one socket and the equipment plugged into it, whereas an SPD in the consumer unit is fitted at the origin of the installation and protects the circuits fed from it; the two are not substitutes for each other and are sometimes used together. A plug-in unit does nothing for hard-wired equipment such as a boiler, a heat pump or an EV charger. James can advise which, if either, suits what you are trying to protect.

Get your surge protection quote

Describe the existing consumer unit and any electrical work you have planned. James reviews the consumer unit and explains the suitable options alongside those planned upgrades.

James aims to reply within one hour, 8am–6pm.

Tap to call 01674 900550
James Leslie

Get a free quote

Replies within an hour, 8am–6pm.

Emergency or out of hours? Call 01674 900550, 24/7.

No obligation. Costs are agreed before any work begins.