Landlord EICR & Electrical Safety Inspections in Montrose
Thorough, plain-English Electrical Installation Condition Reports (EICR) for rental properties, home buyers and business premises in Montrose and across Angus. Speak to James Leslie directly and make sure your rental property satisfies Scottish landlord safety laws.
Call 01674 900550James answers · 24/7 for emergencies- Local, Montrose based electrician
- Written report with photographs
- Sent to your letting agent on request
- Costs agreed before work begins
18th EditionBS 7671 Qualified
City & Guilds2382-22, Level 3
Fully InsuredFor Electrical Work- RAF ElectricianElectrical Engineer
Ex-Retained FirefighterFire & Rescue Service

EICR Testing for Landlords Across Montrose, Angus
Montrose Sparks is James Leslie, based in Montrose. Rented property in the town includes flats above and behind the High Street, older terraces near the South Esk and newer homes at Borrowfield, and he inspects across DD10 and an approximate 40-mile radius.
James does the inspection, the report and any remedial work. With your agreement the report can go straight to your letting agent or solicitor. A rental visit can combine the EICR with Portable Appliance Testing and Interlinked Smoke & Heat Alarms.
5/5 on Google Reviews
“He took great care over the work (even used a spirit level to make sure the cooker was sitting right!) and was very reasonably priced. We are new to the area and struck lucky finding a reliable, responsive electrician.”
“Great service, fast response and problem fixed quickly”
“Great service highly recommended.”
“Jamie arrived within 15 minutes of my call and had the power back on about 10 minutes later.”
“James was very polite and sent over the quote immediately after the call and came out the same day in the early evening.”
“He couldn't of been more helpful and still only took what he quoted for, even though it was a bigger job than expected. Definitely recommend.”
“Arrived within an hour of my call, as he said he would. Fixed the problem same afternoon, and rate was extremely reasonable!”
“They also give decent price for the job and the work done will be using James again, he is also very polite and very helpful too me.”
“Fast response during a weekend, put in a temporary fix so we got power back. Excellent service.”
“Very professional and courteous. Highly recommend him.”
“James answered my call late at night and went to my property to investigate even though I had never used him before.”
The legal position
How Often Do You Need an EICR in Scotland?
Private landlords in Scotland must arrange the required electrical safety inspection before first letting and at intervals of no more than five years, or sooner where the report requires it. A new tenancy does not automatically require a new EICR if a suitable current report remains valid.
Before a property is first let
The required electrical safety inspection must be arranged before first letting.
At intervals of no more than five years
Or sooner where the report itself requires an earlier re-inspection.
A new tenancy does not automatically need a new EICR
If a suitable current report remains valid, a change of tenant does not restart the clock.
Owner-occupied homes
Discuss an appropriate inspection interval based on the installation and any previous report.
What the Inspection Covers
Testing the fixed installation, recorded with observation codes and photographic evidence so you can see what was checked and why.

Consumer Unit & Earthing
Assessing fuse board condition, earthing bonding, and protective devices (RCDs / RCBOs).

Sockets & Wiring Integrity
Testing circuit wiring insulation resistance, polarity, and earth continuity.

Written Report with Photos
Clear photographic evidence of any observation codes (C1, C2, FI) requiring attention.
How Much Does a Landlord EICR Cost?
Pricing for an EICR depends on the size of the property, the number of electrical circuits, and access to the installation. Costs are always discussed and agreed upon before work starts.
- Typical Landlord EICR InspectionSize and layout of property, circuit count, previous report availability. Property details and circuit count discussed upfront.
- £150 – £700+Typical domestic inspection
- Landlord Package (EICR + PAT + Smoke Alarms)Combined testing for rental compliance in a single visit. Tailored to rental property specifications.
- Custom quoteOne visit, combined testing
- Remedial Code Fixing (C1 / C2 Repairs)Scope of code repairs, replacement accessories required. Quoted separately following EICR report findings.
- £60 – £360+Quoted after the report
Indicative guide prices. The final scope and cost are agreed before work begins. Any further remedial repairs identified through testing are quoted separately for your approval before proceeding.
After the inspection
Your EICR Investigation, Explained: Written Reports & Photos
Electrical safety testing shouldn’t leave you guessing about what was checked or why a repair is needed. After every inspection, James provides a clear, private written report detailing:
Photographic Findings
Clear photos showing any damaged fittings, outdated components, or safety issues found during testing.
Completed & Outstanding Work
Clear breakdown of circuits tested, items verified, and areas requiring attention.
Repair & Replacement Options
Understand the lower-cost repair option versus long-term replacement choices.
Electrical Installation Condition Report
A written condition report, including observations and limitations, for your landlord, home-sale or business records. An EICR is not an installation certificate for new work.
Pre-Purchase EICRs
Before buying a home in Montrose or Angus, a pre-purchase EICR reveals hidden electrical defects, outdated wiring, or non-compliant consumer units—helping you negotiate repairs or budget accurately before completing the sale.
Commercial Premises EICRs
Fixed wiring testing for retail shops, offices, workshops, and commercial units to ensure workplace health and safety compliance.
Remedial Code Fixing (C1 / C2 Repairs)
Any further remedial repairs identified through testing are quoted separately for your approval before proceeding. Where the report recommends a new board, that is quoted as a separate Fuse Box & Consumer Unit Upgrades job.
Why Choose Montrose Sparks for Your EICR?
- Montrose Sparks carries out EICRs across Montrose, Angus
Electrical Installation Condition Reports for rental properties, home buyers and business premises. James works from Montrose and covers an approximate 40-mile radius.
- 40 Years of Electrical Engineering Experience
You speak to and deal with James Leslie himself, who brings decades of technical expertise across military, municipal and private sectors.
- Ex-RAF Engineer & Retained Firefighter
James’s background as a firefighter shapes a careful, safety-first approach to preventing electrical fire risk.
- Fully Insured
Comprehensive public liability cover on domestic and commercial properties, for complete peace of mind.

EICR Inspections Across Montrose, Angus
James is based in Montrose, Angus, Scotland, and inspects across the DD10 postcode district, the Angus towns and the Mearns within an approximate 40-mile radius. Give him your postcode to confirm availability.
- Montrose and DD10The town, Ferryden and Hillside, and up the coast to St Cyrus. Our base, so usually the quickest to arrange.
- Brechin and ForfarRental properties, home sales and business premises across the Angus towns.
- ArbroathInspections and remedial work, including surrounding rural properties.
- Laurencekirk and InverbervieEnquiries welcome for houses, flats and rented properties.
- Elsewhere in Angus and the MearnsDundee and Stonehaven are inside the approximate 40-mile service area. Call with your postcode to check coverage.
Frequently Asked Questions About EICR Testing
Can’t see your question?
James answers the phone himself and will tell you straight away whether he can help.
Call 01674 900550How often do I need an EICR certificate in Scotland?
For private rented properties in Scotland, inspections are required before first letting and at intervals of no more than five years, or sooner where specified. A change of tenancy does not automatically require a new report. For owner-occupied homes, discuss an appropriate inspection interval based on the installation and previous report.
Will the power be turned off during the EICR test?
Yes. Electrical testing requires shutting off main power for short periods to safely test circuits, earthing connections, and protective devices. James will inform you in advance so you can prepare.
What happens if my EICR report comes back as “Unsatisfactory”?
C1 (Danger Present), C2 (Potentially Dangerous), or FI (Further Investigation Required) observations result in an unsatisfactory assessment. C1 needs immediate action, C2 needs urgent remedial work, and FI needs investigation without delay. James explains the findings and any proposed further work.
Do you issue landlord EICR reports directly to letting agents?
Yes. We can send the EICR as a PDF directly to your letting agent, solicitor, or property management team with your agreement. It records the condition and findings rather than certifying that remedial work has been completed.
Get your EICR quote
Send the property details, who is living there and any previous report. If you manage several properties, list the addresses and James will quote them together.
James aims to reply within one hour, 8am–6pm.